Saviair Troubleshooting And Repair


Saviair 5000

Troubleshooting Chart

Problem Cause
  • Fan does not operate
  • Both indicator lights off
  • Unit not plugged in
  • Cell access door not fully closed
  • System switch not ON
  • Green light on
  • Red light off
  • Negative Ion switch not in ON position
  • Fan operating
  • Both lights off
  • Cell wet from washing
  • Short in cell (see below)
  • Fan does not operate
  • Green light on
  • Speed selector switch not positioned correctly
  • Fan motor malfunction
  • Cell arcing excessively
  • Cell wet from washing
  • Cell plate(s) bent
  • Cell dirty or large lint ball/hair caught in cell
  • Broken ionizing wire
  • Both indicator lights on But cell not collecting dirt
  • Arrow on cell not pointing towards fan

 

The two operation lights are also used as the high voltage fault indicator. If the fan is operating, but the lights do not come on, then there is a problem in the high voltage circuit. To determine the problem, turn the Air Cleaner OFF and remove the collecting cell. Close the access door and turn the Air Cleaner back ON. If the light comes back on, the problem lies in the collecting cell. Check the cell for wetness from washing or look for a broken ionizing wire or bent cell plate(s). If the lights do not come on, the problem is with the power board or indicator light. If you are unable to correct any of the above problems, call 705-443-8445 for service.


Saviair 500

Troubleshooting Chart

Problem Cause
  • Fan does not operate
  • Both indicator lights off
  • Unit not plugged in
  • Lid not securely closed
  • System switch not ON
  • Fan switch not in proper position
  • Green light on
  • Red light off
  • Negative Ion switch not in ON position
  • Fan operating
  • Both lights off
  • Cell wet from washing
  • Short in cell (see below)
  • Air Cleaner vibrating excessively
  • Unit not sitting on flat surface
  • Cell arcing excessively
  • Cell wet from washing
  • Cell plate(s) bent
  • Cell dirty or large lint ball/hair caught in cell
  • Broken ionizing wire
  • Pre-Filter is in backwards (black foam should be visible on outside)
  • Both indicator lights on But cell not collecting dirt
  • Cell is in backwards (Arrow on cell should point towards fan blower)

 

The two operation lights are also used as the high voltage fault indicator. If the fan is operating, but the lights do not come on, then there is a problem in the high voltage circuit. To determine the problem, turn the Air Cleaner OFF and remove the collecting cell. Close the lid and turn the Air Cleaner back ON. If the light comes back on, the problem lies in the collecting cell.  Check the cell for wetness from washing or look for a broken ionizing wire or bent cell plate(s). If the lights do not come on, the problem is with the power board or operation light(s). If you are unable to correct any of the above problems, call 705-443-8445 for service.